The manual collimators described
in this page are designed to be used for standard medical or veterinary radiographic investigations and are certified as attested in the individual descriptions.
All the collimators are subject to rigorous production and final
testing processes and are delivered with correct mechanical centering
of the x-ray field, with calibration of the field to ensure exact
light-field/x-ray field correspondence. |
|
| R72 |
|
 |
| |
Square-field, single-layer x-ray collimator. This unit is lightweight, compact and is ideal for installation on mobile x-ray equipment. The unit has been designed and manufactured for clinical skeletal and articular investigations of all body areas.
- Mounting at 70 mm from the x-ray focus.
- Maximum radiation protection 125 kVp - 4mA.
- Field size variable from Min: 00 x00 cm to Max: 43 x 43 at
100 cm FFD (SID).
- Light field, simulating the x-ray field, may be provided by a halogen lamp - 24 V DC/AC 50/60 Hz.
- Electronic timer for the activation of the light-field simulating
the x-ray field.
- Minimum inherent filtration 2 mm aluminium equivalent.
- Field size variable from Min: 00 x00 cm to Max: 43 x 43 at
100 cm FFD (SID).
- Retractable measuring tape mounted on the collimator.
|
 |
| R72S |
|
 |
| |
Compact and light, square-field, x-ray collimator suitable for installation on portable x-ray equipment. The unit has been designed and manufactured for clinical skeletal and articular invetigations of all body areas. Possible to install on fixed or rotating anode X-ray tubes.
- Mounting distance from the x-ray focus: 55mm
- High luminosity provided by a white power led (power supply
1 A)
- Timer limiting light source exposure time to 30 seconds
thus extending Led life and preventing overheating.
- Maximum radiation protection: 125 kVp -4 mA
- Minimum inherent filtration: 2 mm aluminium equivalent (1mm
on request) .
- Continuous film coverage from Min: 00 x 00 cm to Max: 43
x 43 cm at 100 cm FFD (SID).
- Retractable tape measure.
|
 |
| R104 |
|
 |
| |
Square-field, single-layer x-ray collimator. This unit is lightweight, compact and is ideal for installation on portable x-ray equipment with fixed
anode x-ray tubes. Steel covers.
- Mounting at 80 mm (3.14") from the x-ray focus
- Maximum radiation protection 125 kVp.
- Two knobs on the front panel of the collimator provide for
the manual control of shutters.
- Light field, simulating the x-ray field, may be provided by a halogen lamp.
- Electronic timer for the activation of the light-field simulating
the x-ray field.
- Minimum inherent filtration: 2 mm aluminium equivalent (1mm
on request) .
- Field size variable from Min: 00 x00 cm to Max: 43 x 43 at
100 cm FFD (SID).
|
 |
| R104/A |
|
 |
| |
Square-field, single-layer x-ray collimator. This unit is lightweight, compact and is ideal for installation on portable x-ray equipment with fixed
anode x-ray tubes. Plastic covers
Operation with rotating anode x-ray tubes requires the
adoption an optional item RO
278.
- Mounting at 80 mm (3.14") from the x-ray focus.
- Maximum radiation protection 125 kVp.
- Two knobs on the front panel of the collimator provide for
the manual control of shutters.
- Light field, simulating the x-ray field, may be provided by a halogen lamp or, on request, by a white power Led.
- Electronic timer for the activation of the light-field simulating
the x-ray field.
- Minimum inherent filtration: 2 mm aluminium equivalent (1mm
on request) .
- Field size variable from Min: 00 x00 cm to Max: 43 x 43 at
100 cm FFD (SID).
certifications |
|
FDA |
|
 |
| R105 |
|
 |
| |
Square-field, single-layer x-ray collimator. This unit is lightweight, compact and is ideal for installation on portable x-ray equipment with fixed
anode x-ray tubes. Steel covers.
- Mounting at 100mm from the x-ray focus
- Maximum radiation protection 125 kVp.
- Two knobs on the front panel of the collimator provide for
the manual control of shutters.
- Light field, simulating the x-ray field, may be provided by a halogen lamp.
- Electronic timer for the activation of the light-field simulating
the x-ray field.
- Minimum inherent filtration: 2 mm aluminium equivalent (1mm
on request) .
- Field size variable from Min: 00 x00 cm to Max: 43 x 43 at
100 cm FFD (SID)
|
 |
| R108 |
|
 |
| |
Square-field, multi-layer x-ray collimator. This unit is lightweight, compact and is ideal for installation on stationary and mobile units with fixed or rotating anode x-ray
tubes. Plastic covers
- Mounting at 80mm (3.14") from the x-ray focus
- Maximum radiation protection 125 kVp. (150 kVp on request)
- Two knobs on the front panel of the collimator provide for
the manual control of shutters.
- Light field, simulating the x-ray field, may be provided by a halogen lamp or white power Led (RO333).
- Timer limiting projection exposure time to 30 seconds thus
extending light source life by preventing overheating.
- Minimum inherent filtration: 2 mm aluminium equivalent (1mm
on request) .
- Field size variable from Min: 00 x00 cm to Max: 43 x 43 at
100 cm FFD (SID)
|
 |
| R108F |
|
 |
| |
Square-field, multi-layer x-ray collimator. This unit is lightweight, compact and is ideal for installation on stationary and mobile units with fixed or rotating anode x-ray
tubes. Plastic covers.
R108F is designed to accommodate additional variable filtration on an aluminium disc with manual control.
- Mounting distance from the x-ray focus: 80 mm (3.14").
- Mirror adjustment.
- X-ray field simulated by light field provided by a white power Led.
- Timer limiting projection exposure time to 30 seconds thus
extending led life by preventing overheating.
- Retractable measuring tape.
- Maximum radiation protection: 125 kVp – 4mA (150 kVp on request).
- Minimum inherent filtration: 2 mm aluminium equivalent (1mm
on request) .
- Variable square-field from: Min: 00 x 00 cm a Max: 43 x 43
cm at 100 cm FFD-SID.
|
 |
| R221/A |
|
 |
| |
Square-field, multi-layer x-ray collimator. This unit is lightweight, compact and is ideal for installation on stationary and mobile units with fixed or rotating anode x-ray
tubes. Plastic covers.
- Mounting at 80 mm (3.14") from the x-ray focus.
- Mirror adjustment.
- Light field, simulating the x-ray field, may be provided by a halogen lamp or white power Led (RO333).
- Timer limiting projection exposure time to 30 seconds thus
extending light source life by preventing overheating.
- Retractable measuring tape.
- Maximum radiation protection 150 kVp - 4mA.
- Minimum inherent filtration: 2 mm aluminium equivalent (1mm
on request RO 108) .
- Field size variable from Min: 00 x00 cm to Max: 48 x 48 at
100 cm FFD (SID)
|
 |
| R302/A |
|
 |
| |
Square-field, multi-layer x-ray collimator. This unit is ideal for installation on stationary units with fixed or rotating anode x-ray
tubes.
Plastic covers.
- Mounting at 80 mm (3.14") from the x-ray focus.
- Mirror adjustment.
- Light field, simulating the x-ray field, may be provided by a halogen lamp or white power Led (RO333).
- Timer limiting projection exposure time to 30 seconds thus
extending light source life by preventing overheating.
- Retractable Measuring tape.
- Maximum radiation protection 150 kVp.
- Minimum inherent filtration: 2 mm aluminium equivalent (1mm on request).
- Field size variable from Min: 00 x00 cm to Max: 48 x 48 at
100 cm FFD (SID) .
|
 |
| R302L/A |
|
 |
| |
Square-field, multi-layer x-ray collimator. This unit is ideal for installation on stationary units with fixed or rotating anode x-ray
tubes. Plastic covers.
This model features Laser alignment of Potter Bucky/collimator.
- Mounting at 80 mm (3.14") from the x-ray focus.
- Mirror adjustment.
- Light field, simulating the x-ray field, may be provided by a halogen lamp or white power Led (RO333).
- Timer limiting projection exposure time to 30 seconds thus
extending light source life by preventing overheating.
- Retractable Measuring tape.
- Maximum radiation protection 150 kVp.
- Minimum inherent filtration: 2 mm aluminium equivalent (1mm on request).
- Field size variable from Min: 00 x00 cm to Max: 48 x 48 at
100 cm FFD (SID).
|
 |
| R302F/A |
|
 |
| |
Square-field, multi-layer x-ray collimator. This unit is ideal for installation on stationary units with fixed or rotating anode x-ray
tubes. Plastic covers
This model is designed to accommodate additional variable filtration on an aluminium disc with manual control.
- Mounting at 80 mm (3.14") from the x-ray focus.
- Mirror adjustment.
- Light field, simulating the x-ray field, may be provided by a halogen lamp or white power Led (RO333).
- Timer limiting projection exposure time to 30 seconds thus
extending light source life by preventing overheating.
- Retractable Measuring tape.
- Maximum radiation protection 150 kVp.
- Minimum inherent filtration: 2 mm aluminium equivalent (1mm on request).
- Field size variable from Min: 00 x00 cm to Max: 48 x 48 at
100 cm FFD (SID).
|  |
| |
|
|